Features
- Drop-in compatible for lead acid battery, maintenance Free
- About 40% – 70% of the weight of a comparable lead acid battery
- 100 A discharge; charges in 2 hours
- Safe: Lithium Iron Phosphate cells, no hazardous gases
- Thousands of cycles, to 100% DOD, under normal conditions
- Built-in protector BMS with cell balancing: over-charge, over discharge, over-current and over-temperature
- Wide temperature range:-20 – 60 ℃ ℃
- Supports up to 2 batteries in Series (51.2V)
- 6 year limited warranty
- Some battery components may be recycled or repurposed
APPLICATIONS
- UPS
- Solar & Wind Power System
- Mobility
- Electric Vehicle, E-bike, E-Rickshaw etc.
- Lighting
- Leisure and Marine
[vc_custom_heading text=”Specifications” use_theme_fonts=”yes”]
Specifications | Min | Normal | Max | unit | ||
Electrical | Voltage | Open circuit, 2 hours relaxation | 24.0 | 26.6 | 28.8 | V |
Capacity | 1/20 C | 100 | Ah | |||
Energy | 1/20 C | 2560 | Wh | |||
Internal Resistance | 25 ℃ | 26 | mΩ | |||
Cycle Life | 0.5C charging/discharging,25 , to 90% of nominal capacity | 2000 | cycles | |||
Self Discharge | 3.5 | %/month | ||||
Mechanical | Dimension | Including terminals | 522 x 240 x224 | mm | ||
Connection | M8 bolts | |||||
Mass | 19 | kg | ||||
Ingress Protection | IP55 | |||||
Operating Conditions | ||||||
CCCV charging |
Constant current | CC stage (“bulk”) | 50 | A | ||
Peak current | 10 s max (“regen”) | 100 | A | |||
Constant voltage | CV stage ( “absorption”), until current drops below 5 A, 2 hr max | 27.4 | 27.6 | 28.8 | V | |
Float voltage | 26.8 | 27.0 | V | |||
Temperature | -20 | 60 | ℃ | |||
Environmental | Temperature | 0 | 45 | ℃ | ||
Humidity | 35 | 75 | % | |||

[vc_custom_heading text=”Battery Care” use_theme_fonts=”yes”]
Storage:
- Bring to ~50 % charge, then store in a cool, dry place
- Do not drop
Charging:
- A CV stage that lasts too long degrades the battery rapidly
- Stand-by applications: exceeding 26.8V degrades the battery
- Charging is disabled below freezing; warm the battery first
- Maximize capacity by regularly charging to the specified voltage
Discharging:
- If no voltage, the battery is off; charge it to wake it up